Fire Alarm & Detection System

  • Smoke Detector
  • Multi Detector
  • Heat Detector
  • Manual Call Point
  • Fire Control Panel
  • Repeater Panel
  • Sounder & Strobe
  • Input/ Output Module
  • Beam Detector

Smoke Detector

Description

Photoelectric smoke sensor (opto) is suitable for most applications giving the fastest response to slow burning or shouldering fires which give rise to large visible smoke particles.

Features

  • Built-in short circuit isolators
  • Stylish low profile design
  • 360º viewable LED design
  • Removable detector chamber
  • Drift compensation

Benefits

  • Plug and play – no hard addressing required
  • Clean me’ feature means sensor can be cleaned on site using Eaton’s manual cleaning procedure
  • The programmable heat sensor reduces the number of parts required in the system

Multi Detector

Description

Opto-heat sensor will respond better to fast clean burning fires yet maintain the advantage of optical sensors when detecting smoldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also give an alarm at temperatures above 135°F.

Features

  • Built-in short circuit isolators
  • Stylish low profile design
  • 360º viewable LED design
  • Removable detector chamber
  • Drift compensation

Benefits

  • Plug and play – no hard addressing required
  • Clean me’ feature means sensor can be cleaned on site using Eaton’s manual cleaning procedure
  • The programmable heat sensor reduces the number of parts required in the system

Heat Detector

Description

Rate of rise with fixed heat sensor settings will detect a rapid increase in temperature or temperatures above 135°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.

Features

  • Built-in short circuit isolators
  • Stylish low profile design
  • 360º viewable LED design
  • Removable detector chamber
  • Drift compensation

Benefits

  • Plug and play – no hard addressing required
  • Clean me’ feature means sensor can be cleaned on site using Eaton’s manual cleaning procedure
  • The programmable heat sensor reduces the number of parts required in the system

Manual Call Point

Description

The UL pull stations (UMPS-100 and UMPS-200) are designed to exceed your expectations and offer the most polished, feature rich and cost effective solution. Both the (UMPS-100 and UMPS-200) are compatible with Eaton’s UL range of intelligent addressable fire systems, and come complete with a (ULMCIM-C) fast response intelligent addressable input initiating unit.

This UL pull station is constructed of high quality, die-cast metal for long lasting performance and is designed to be fitted to a single gang back-box for flush mounting. For surface mounting a sheet metal back box (SBG325) can be utilized.

The (UMPS-100 and UMPS-200) are painted red with raised white lettering, have a locking mechanism to prevent unauthorized reset and are complete with a UL Listed fast response intelligent addressable input initiating module (ULMCIM-C)

Features

  • Mounting: Wall
  • Single or dual action
  • Terminal Strip Connections
  • Key Reset
  • Corrosion resistant
  • Single gang back box
  • Class A, style 7 SLC

Benefits

  • High quality die cast metal case for lasting performance
  • Plug and play – no hard addressing require

Fire Control Panel

Description

The control panel has the ability to support complex cause and effect programming and a wide range of user-controllable functions make the system ideal for a diverse range of projects from industrial applications through to large multi-site commercial developments.

The ULCF3000 uses soft addressing to minimize installation time and remove the potential for error associated with manual addressing.

Each of the system components have been specifically designed to operate as part of a ULCF3000 UL Listed system providing assurance that the panel, the detectors, the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Features

  • Touchscreen Display
  • 2 or 4 Class A Style 7 SLC loops
  • Event History Buffer (9,999 events) with Date/Time stamp
  • 4 Notification appliance circuits (NAC’s) outputs
  • 3 programmable general purpose relays
  • Dedicated alarm and trouble relays
  • Short circuit isolators incorporated into each loop
  • Up to 200 addresses per loop
  • Fully monitored network cable up to 126 panels
  • Optional integral printer
  • Alarm Verification
  • PAS (Positive Alarm Sequence)
  • Pre-Signal per Point (NFPA 70, 72 compliant)
  • Remote Alarm, NAC silenced, Alarm Reset, Trouble, Supervisory and drill via addressable module

Benefits

  • Supports a comprehensive range of soft addressing modules and devices for greater flexibility in design
  • Menu driven graphical user interface for ease of operation
  • Reduced commissioning time through soft addressing and auto learn functions
  • Programming and trouble-shooting time minimized by using a range of features such as auto config, walk test, system details, analogue values, etc.

Repeater Panel

Description

The ULCTPR3000 repeater panel provides sophisticated ‘touch screen’ functionality yet achieves a simple end-user interface operation within a compact panel design.

The ULCTPR3000 is designed to work with all UL Listed Cooper analogue fire alarm control panels as a network repeater. Eaton’s ‘touch-screen’ repeater panel is easy to install and commission. All text is transmitted via the network and is automatically updated.

Features

  • Plug and play. All information is downloaded through the network
  • Touch-screen display
  • Integrated network capability allows networking with the latest Eaton range of analogue fire alarm control panels
  • Multi language capability
  • PSU approved to EN54 pt4 and UL864 9th Edition
  • Up to 126 repeaters can be connected to the network
  • Programmable as an active or passive repeater
  • Dual redundant network card to enhance system integrity

Benefits

  • Plug and play requires no programming
  • Easy to operate touch screen display
  • System integrity, fire alarm system continues to operate even if there is a short circuit or open joint on cable
  • Easy to change the language to suit the operator

Sounder & Strobe

Description

The UL range of notification devices are designed to exceed your expectations and offer the most polished, feature rich and cost effective solution.

Both stylish and inspiring, architects and engineers can now specify the industry’s sleekest looking fire notification appliance, while being afforded all the features and benefits that provide the industry’s lowest total cost of ownership.

Features

  • 80% reduction in SKUs – Up to 9 models now in 1 appliance
  • 3 audible settings
  • 8 candela settings in 1 device
    Wall – 15/1575/30/75/95/110/135/185
    Ceiling – 15/30/60/75/95/115/150/177
  • A combination of 12 and 24 VDC in one appliance providing the capability to use a single appliance for different installation requirements
  • A universal, common base for retrofit jobs, limited space environments and pre-existing wire configurations. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues

Benefits

  • Up to 48% savings in current draw over similar products, with the latest horn/strobe products you can install more appliances per a given circuit
  • A combination of 12 and 24 VDC in one appliance
  • Easier to install – Save up to 14% cost of installation**
  • 5 Mounting Options – 1 gang,
  • 2 gang, 4”sq., 3.5 octal, 4” octal box
  • Voltage test points for quick troubleshooting and easy spot checking
  • 1/16” deep mounting error relief Pre-wire capability to check for wiring & ground faults prior to appliance installation
  • Contact cover not only provides protection from dirt, dust, paint and accidental damage, it allows for pre-wire testing and troubleshooting

Input/output Module

Description

An extensive range of interfaces are available to support the Cooper range of UL control panels, providing solutions for most design requirements.The ULMCIM and ULMCIM-C are designed for use with water flow switches and other applications requiring the monitoring of dry contact alarm devices.The ULMCIM and ULMCIM-C are single channel input units and are extremely compact and therefore ideal for incorporation into other equipment.The ULMCIM-C is designed for use with Pull Stations (fast response to alarm).The ULMCIM-C is identified by the panel as a call point.

Features

  • Quick and simple to install
  • Compact size
  • Soft Addressed
  • Integral short circuit isolator

Benefits

  • Plug and play – no hard addressing required
  • No external short circuit isolator required

Beam Detector

Description

The new Simplex Addressable Beam Detector combines the power and flexibility of IDNet technology with the proven performance of the Fire Ray 5000 optical beam smoke detector. Beam Detectors are used to provide “open area” smoke detection in situations where it is either impractical or not cost effective to use traditional point-type detectors or aspirating smoke detection. Some common applications are: Warehouses; Atriums; Convention Centers; Shopping Malls; Sports Arenas.

The addressable beam detector provides enhanced command, control, configuration and status / event reporting between the detector and the fire alarm control panel. Configuration, installation, diagnostics, service and maintenance of this new addressable detector is also simpler and faster than a conventional detector and separate IDNet module, saving time and money for contractors, installers and building owners.

Features

  • Up to 2 Detector Heads reporting to One Ground Level Controller
  • Range of 26 ft, 3 inches to 330 ft (8 m to 100 m)
  • Built in Laser assisted prism mounting
  • Built-In electronic UL/ULC obscuration acceptance Fire Test
  • Contamination compensation
  • Fire alarm control panel operations include: Sensitivity selection, Almost Dirty threshold, Initiate obscuration test
  • Fire alarm control panel information received includes: Smoke status, controller-to-detector communications status, trouble status, Analog values for signal strength and compensation level

Benefits

  • The system is designed to be mounted so the beam will project between 19” (0.5m) and 24” (0.6m) below and parallel to the ceiling.
  • Lateral detection may be up to 30ft. (9.144m) on either side of the beam, providing a maximum total coverage area of up to 19,800 square feet (60ft. x 330ft. or 18.29m x 100m).

Download Our Brochure